Welcome to EquiLab Canada Inc.

 

 

Home

Contacts

Resources

Links

 

Products

 

Environment

 

Life Science

 

General use

 

Petroleum Testers

 

Glassware

 

Consumables

 

Accessories

 

Spare Parts

 

 

 

COD C 9800 Reactor

COD Reagents

COD C99 Photometer

 

 

C 9800 Reactor

 

      
                                          

       Features

·         Performs up to 25 samples simultaneously

·         150ºC (COD) or 105ºC (Total Phosphorus,   

        Total Nitrogen) selectable temperatures

·         Timer (up to 120 min.) with audible alarm

        incorporated

·         On/Off LED and heating LED indicators

·         Over-heating protection

 

 

Specifications

C 9800-02

C9800-02

Ambient Operating Temperature

+5 to +50 °C

 

Storage Temperature

-20 to +60 °C

 

Temperature Stability

±0.5 °C

 

Capacity

25 of 16 x 100 mm vials, 1 receptacle for stainless steel probe thermometer

 

Accuracy

±2 °C @ 25 °C ambient

 

Warm-up Time

30-40 minutes, depending on set temperature

 

Temperature Setting

Selectable temperature @ 105 °C or 150 °C

 

Operating Mode

Timed procedure (0 - 20 min.) or infinity mode

 

Timer

0-120 minutes with acoustic alarm and automatic shut-off mode

 

Block

Aluminum

 

Power Requirements

115 VAC; 60Hz; 250W; Fuse 4A

230 VAC; 50Hz; 250W; Fuse 2A

 

Dimensions

190 x 300 x 95 mm (7.5 x 11.8 x 3”)

 

Weight

Approx. 4.8 kg (10.6 lb.)

 

 

 

 

 

Optional Accessories

HI 740142

Graduated syringe

HI 740143

Graduated syringe (6 pcs)

HI 98517

K-type thermometer for Hanna reactor

HI 740216

Test tube cooling rack (25 holes)

HI 740217

Laboratory bench safety shield

 

 

COD Reagents

 

 


 



• Official dichromate method
 in accordance with Standard Methods 5220D and USEPA method 410.4.

• Sample size required: 2 ml
vials with a diameter of 16 mm  contain 3 mL of pre-dosed reagent.

Three ranges of COD measuring applications:

· HI 93754A-25 Low Range: 0-150 mg/L O2

· HI 93754B-25 Medium Range: 0-1500 mg/L O2

· HI 93754C-25 High Range: 0-15000 mg/L O2

 

 

C 99 Multi-parameter Photometer with COD

 

 

        


C 99 COD meter  is a compact photometer operating in three different ranges, to cover virtually every application: 0-150 mg/L, 0-1500 mg/L and 0-15000 mg/L.

The C 99 meets the design requirements of USEPA 410.4, guaranteeing high quality measurements to be used for reporting purposes.

A built-in RS232 port allows the user to connect to a PC. The C 99 can be operated manually or from the PC and data can be downloaded for analysis and documentation purposes with Hanna's HI 92000 software.

C 99 Specifications

0 - 150 mg/L COD Range

0 - 1500 mg/L COD Range

0 - 15000 mg/L COD Range

Range

0 - 150 mg/L (ppm)

0 - 1500 mg/L (ppm)

0 - 15000 mg/L (ppm)

Resolution

1 mg/L

1 mg/L

10 mg/L

Precision (std. dev.)

(@150 mg/L) ±4 mg/L

(@ 1000 mg/L) ±22 mg/L

(@10000 mg/L) ±220 mg/L

Operating Wavelength

Tungsten lamp with narrow band
interference filter @ 420 nm

Tungsten lamp with narrow band interference filter @ 610 nm

Tungsten lamp with narrow band
interference filter @ 610 nm

Method

Adaptation of the EPA 410.4 approved method.

Computer Interface

RS232C

Power Supply

12 VDC power adapter / 2 x 9V battery

Dimensions

230 x 165 x 70 mm (9.0 x 6.5 x 2.8”)

Weight

640 g (22.6 oz.)

 

 

 

 

 

 

 

 In addition to COD, C 99 measures up to 36 of the most important water quality parameters in the following ranges:

 

Test

Range

Method

Reagent Code

Aluminum

0.00 to 1.00 mg/L

Aluminon

HI 93712-01

Ammonia HR

0.00 to 9.99 mg/L

Nessler

HI 93715-01

Ammonia LR

0.00 to 3.00 mg/L

Nessler

HI 93700-01

Bromine

0.00 to 8.00 mg/L

DPD

HI 93716-01

Free Chlorine *

0.00 to 2.50 mg/L

DPD

HI 93701-01

Total Chlorine *

0.00 to 3.50 mg/L

DPD

HI 93711-01

Chlorine Dioxide

0.00 to 2.00 mg/L

Chlorophenol Red

HI 93738-01

Chromium VI HR

0 to 1000 µg/L

Diphenylcarbohydrazide

HI 93723-01

Chromium VI LR

0 to 300 µg/L

Diphenylcarbohydrazide

HI 93749-01

COD LR

0 to 150 mg/L

Dichromate

HI 93754A-25

COD MR

0 to 1500 mg/L

Dichromate

HI 93754B-25

COD HR

0 to 15000 mg/L

Dichromate

HI 93754C-25

Color

0 to 500 PCU

Chloroplatinate

Copper HR

0.00 to 5.00 mg/L

Bicinchoninate

HI 93702-01

Copper LR

0 to 990 µg/L

Bicinchoninate

HI 93747-01

Cyanide

0.000 to 0.200 mg/L

Pyridine-Pyrazalone

HI 93714-01

Cyanuric Acid

0 to 80 mg/L

Turbidimetric

HI 93722-01

Fluoride

0.00 to 2.00 mg/L

SPADNS

HI 93729-01

Ca Hardness

0.00 to 2.70 mg/L

Calmagite

HI 93720-01

Mg Hardness

0.00 to 2.00 mg/L

EDTA

HI 93719-01

Hydrazine

0 to 400 µg/L

p-Dimethylaminobenzaldehyde

HI 93704-01

Iodine

0.0 to 12.5 mg/L

DPD

HI 93718-01

Iron HR

0.00 to 5.00 mg/L

Phenantroline

HI 93721-01

Iron LR

0 to 400 µg/L

TPTZ

HI 93746-01

Manganese HR

0.0 to 20.0 mg/L

Periodate Oxidation

HI 93709-01

Manganese LR

0 to 300 µg/L

PAN

HI 93748-01

Molybdenum

0.0 to 40.0 mg/L

Mercaptoacetic Acid

HI 93730-01

Nickel HR

0.00 to 7.00 g/L

Photometric

HI 93726-01

Nitrate

0.0 to 30.0 mg/L

Cadmium Reduction

HI 93728-01

Nitrite HR

0 to 150 mg/L

Ferrous Sulfate

HI 93708-01

Nitrite LR

0.00 to 0.35 mg/L

Diazotization

HI 93707-01

Dissolved Oxygen

0.0 to 10.0 mg/L

Winkler

HI 93732-01

pH

5.9 to 8.5 pH

Phenol Red

HI 93710-01

Phosphate HR

0.0 to 30.0 mg/L

Amino Acid

HI 93717-01

Phosphate LR

0.00 to 2.50 mg/L

Ascorbic Acid

HI 93713-01

Phosphorus

0.0 to 15.0 mg/L

Amino Acid

HI 93706-01

Silica

0.00 to 2.00 mg/L

Heteropoly blue

HI 93705-01

Silver

0.000 to 1.000 mg/L

PAN

HI 93737-01

Zinc

0.00 to 3.00 mg/L

Zincon

HI 93731-01

* For chlorine measurements, liquid reagents are also available.

 