COD C 9800 Reactor

COD Reagents

COD C99 Photometer

 

 

C 9800 Reactor

 




Features

         Performs up to 25 samples simultaneously

         150C (COD) or 105C (Total Phosphorus,

Total Nitrogen) selectable temperatures

         Timer (up to 120 min.) with audible alarm

incorporated

         On/Off LED and heating LED indicators

         Over-heating protection

 

 

Specifications

C 9800-02

C9800-02

Ambient Operating Temperature

+5 to +50 C

 

Storage Temperature

-20 to +60 C

 

Temperature Stability

0.5 C

 

Capacity

25 of 16 x 100 mm vials, 1 receptacle for stainless steel probe thermometer

 

Accuracy

2 C @ 25 C ambient

 

Warm-up Time

30-40 minutes, depending on set temperature

 

Temperature Setting

Selectable temperature @ 105 C or 150 C

 

Operating Mode

Timed procedure (0 - 20 min.) or infinity mode

 

Timer

0-120 minutes with acoustic alarm and automatic shut-off mode

 

Block

Aluminum

 

Power Requirements

115 VAC; 60Hz; 250W; Fuse 4A

230 VAC; 50Hz; 250W; Fuse 2A

 

Dimensions

190 x 300 x 95 mm (7.5 x 11.8 x 3)

 

Weight

Approx. 4.8 kg (10.6 lb.)

 

 

 

 

 

Optional Accessories

HI 740142

Graduated syringe

HI 740143

Graduated syringe (6 pcs)

HI 98517

K-type thermometer for Hanna reactor

HI 740216

Test tube cooling rack (25 holes)

HI 740217

Laboratory bench safety shield

 

 

COD Reagents

 

 





Official dichromate method
in accordance with Standard Methods 5220D and USEPA method 410.4.

Sample size required: 2 ml
vials with a diameter of 16 mm contain 3 mL of pre-dosed reagent.

Three ranges of COD measuring applications:

HI 93754A-25 Low Range: 0-150 mg/L O2

HI 93754B-25 Medium Range: 0-1500 mg/L O2

HI 93754C-25 High Range: 0-15000 mg/L O2

 

 

C 99 Multi-parameter Photometer with COD

 




C 99 COD meter is a compact photometer operating in three different ranges, to cover virtually every application: 0-150 mg/L, 0-1500 mg/L and 0-15000 mg/L.

The C 99 meets the design requirements of USEPA 410.4, guaranteeing high quality measurements to be used for reporting purposes.

A built-in RS232 port allows the user to connect to a PC. The C 99 can be operated manually or from the PC and data can be downloaded for analysis and documentation purposes with Hanna's HI 92000 software.

C 99 Specifications

0 - 150 mg/L COD Range

0 - 1500 mg/L COD Range

0 - 15000 mg/L COD Range

Range

0 - 150 mg/L (ppm)

0 - 1500 mg/L (ppm)

0 - 15000 mg/L (ppm)

Resolution

1 mg/L

1 mg/L

10 mg/L

Precision (std. dev.)

(@150 mg/L) 4 mg/L

(@ 1000 mg/L) 22 mg/L

(@10000 mg/L) 220 mg/L

Operating Wavelength

Tungsten lamp with narrow band
interference filter @ 420 nm

Tungsten lamp with narrow band interference filter @ 610 nm

Tungsten lamp with narrow band
interference filter @ 610 nm

Method

Adaptation of the EPA 410.4 approved method.

Computer Interface

RS232C

Power Supply

12 VDC power adapter / 2 x 9V battery

Dimensions

230 x 165 x 70 mm (9.0 x 6.5 x 2.8)

Weight

640 g (22.6 oz.)

 

 

 

 

 

 

 

In addition to COD, C 99 measures up to 36 of the most important water quality parameters in the following ranges:

 

Test

Range

Method

Reagent Code

Aluminum

0.00 to 1.00 mg/L

Aluminon

HI 93712-01

Ammonia HR

0.00 to 9.99 mg/L

Nessler

HI 93715-01

Ammonia LR

0.00 to 3.00 mg/L

Nessler

HI 93700-01

Bromine

0.00 to 8.00 mg/L

DPD

HI 93716-01

Free Chlorine *

0.00 to 2.50 mg/L

DPD

HI 93701-01

Total Chlorine *

0.00 to 3.50 mg/L

DPD

HI 93711-01

Chlorine Dioxide

0.00 to 2.00 mg/L

Chlorophenol Red

HI 93738-01

Chromium VI HR

0 to 1000 g/L

Diphenylcarbohydrazide

HI 93723-01

Chromium VI LR

0 to 300 g/L

Diphenylcarbohydrazide

HI 93749-01

COD LR

0 to 150 mg/L

Dichromate

HI 93754A-25

COD MR

0 to 1500 mg/L

Dichromate

HI 93754B-25

COD HR

0 to 15000 mg/L

Dichromate

HI 93754C-25

Color

0 to 500 PCU

Chloroplatinate

Copper HR

0.00 to 5.00 mg/L

Bicinchoninate

HI 93702-01

Copper LR

0 to 990 g/L

Bicinchoninate

HI 93747-01

Cyanide

0.000 to 0.200 mg/L

Pyridine-Pyrazalone

HI 93714-01

Cyanuric Acid

0 to 80 mg/L

Turbidimetric

HI 93722-01

Fluoride

0.00 to 2.00 mg/L

SPADNS

HI 93729-01

Ca Hardness

0.00 to 2.70 mg/L

Calmagite

HI 93720-01

Mg Hardness

0.00 to 2.00 mg/L

EDTA

HI 93719-01

Hydrazine

0 to 400 g/L

p-Dimethylaminobenzaldehyde

HI 93704-01

Iodine

0.0 to 12.5 mg/L

DPD

HI 93718-01

Iron HR

0.00 to 5.00 mg/L

Phenantroline

HI 93721-01

Iron LR

0 to 400 g/L

TPTZ

HI 93746-01

Manganese HR

0.0 to 20.0 mg/L

Periodate Oxidation

HI 93709-01

Manganese LR

0 to 300 g/L

PAN

HI 93748-01

Molybdenum

0.0 to 40.0 mg/L

Mercaptoacetic Acid

HI 93730-01

Nickel HR

0.00 to 7.00 g/L

Photometric

HI 93726-01

Nitrate

0.0 to 30.0 mg/L

Cadmium Reduction

HI 93728-01

Nitrite HR

0 to 150 mg/L

Ferrous Sulfate

HI 93708-01

Nitrite LR

0.00 to 0.35 mg/L

Diazotization

HI 93707-01

Dissolved Oxygen

0.0 to 10.0 mg/L

Winkler

HI 93732-01

pH

5.9 to 8.5 pH

Phenol Red

HI 93710-01

Phosphate HR

0.0 to 30.0 mg/L

Amino Acid

HI 93717-01

Phosphate LR

0.00 to 2.50 mg/L

Ascorbic Acid

HI 93713-01

Phosphorus

0.0 to 15.0 mg/L

Amino Acid

HI 93706-01

Silica

0.00 to 2.00 mg/L

Heteropoly blue

HI 93705-01

Silver

0.000 to 1.000 mg/L

PAN

HI 93737-01

Zinc

0.00 to 3.00 mg/L

Zincon

HI 93731-01

* For chlorine measurements, liquid reagents are also available.

 