K43041 Foaming Characteristics Apparatus, Sequence IV


 

Test Method
Foaming of lubricating oils in applications involving turbulence, high speed gearing or high volume pumping can cause inadequate lubrication, cavitation, overflow and premature oxidation. The sample is blown with a controlled volume of air at different specified temperatures, including a newer high temperature test at 150C. The resultant foam is measured at the end of each aeration period and at different intervals afterward. In the high temperature test, the amount of time required for the foam to collapse to “0” after the aeration period is also measured.

Features and Benefits

• Dual-twin models for standard foaming characteristics tests

• High temperature liquid baths for ‘Sequence IV’ tests

• Automatic time sequence models for both tests

• Custom configurations for specialized applications


 

K43041 Foaming Characteristics Apparatus, Sequence IV
For two tests at 150C with a flow rate of 200mL/min in accordance with ASTM D6082 specifications. Consists of a constant temperature bath with 1000mL test cylinders, certified diffusers, air delivery tubes and flowmeters. Microprocessor PID control provides quick temperature stabilization without overshoot and the bath is protected by an overtemperature control circuit that interrupts power should bath temperature exceed a programmed cut-off point. Dual LED displays provide actual and setpoint temperature values in C/F format. Quick response copper immersion heaters provide efficient high temperature operation, and a stirrer unit provides complete circulation for temperature uniformity of better than 1F (0.5C). Locking cams hold the test cylinders in a vertical position, and a separate rack is provided to hold the cylinders after removal from the bath. For operator safety, an acrylic heat shield surrounds the Pyrex™ bath jar. Communications software (RS232, etc.), ramp-to-set and other enhanced features are available as extra cost options. Contact your Koehler representative for information.

Custom Configurations
In addition to the standard configurations described, Koehler liquid-bath foaming characteristics test equipment can be ordered in the following custom configurations:
• Dual-Twin 24C/D892-150C/D6082
• Dual-Twin 93.5C/D892-150C/D6082
• Single-Bath model for ASTM D892 (for 24C and 93.5C tests)
Custom models have the same operating features and characteristics as the standard models and each bath is equipped with the necessary air flow and control accessories required to perform the applicable test method. Contact your Koehler representative for ordering information and pricing.

Included Accessories
Test Cylinders, 1000mL
Diffuser Stones, calibrated and certified
Air Delivery Tube Assemblies
Air Outlet Tube
Rubber Stoppers
Bath Jar
Support Rack

Specifications
Conforms to the specifications of: ASTM D6082

Air Flow Rate: 200mL/min

Bath Temperature: 150C (302F) - Operator Variable

Bath Capacity: 9 gal (38.5L)

Temperature Control:
Digital Setpoint and Displays C/F switchable
Built-in Overtemperature Cut-off Protection

Electrical Requirements
115V, 50/60Hz, 14A
220-240V, 50/60Hz, 7A

Dimensions lxwxh,in.(cm)
16.75x15x31.25 (42.5x38x79.4)
Net Weight: 62 lbs (28.1kg)

Shipping Information
Shipping Weight: 89 lbs (40.4kg)
Dimensions: 16.3 Cu. ft.


Ordering Information

 

Catalog
Number

Product Description

Electrical Requirements

K43041

Foaming Characteristics Apparatus, Sequence IV

115V 50/60Hz

K43049

Foaming Characteristics Apparatus, Sequence IV

220-240V 50/60Hz


Accessories

 

Catalog Number

Product Description

387-115-001

Air Pump, oil-less.
Delivers 100% oil-free air. 115V, 50/60Hz

387-230-001

Air Pump, oil-less.
Delivers 100% oil-free air. 220-240V, 50/60Hz

K43026

Wet Test Gas Meter
For volume measurements of air leaving the test cylinders. Note: One meter is required for each test cylinder. Not required for the ‘Alternative Procedure’ - Section 9.1

332-005-005

Drying Tower. 300mm

K43025

Diffuser Stone Test Apparatus
For maximum pore diameter and permeability tests on diffuser stones. Consists of 90cm manometer, 500mL flask, flowmeter, graduate, delivery tube assembly and control valve.

K33031

Refrigerated Recirculator, 115V 60Hz, 8A
Use with foam test baths for 24C tests (Sequence I and III). Microprocessor based digital control and quiet running compressor provide reliable operation and accurate control within 0.5C.

K33032

Refrigerated Recirculator, 220-240V 50Hz, 4A

250-000-12F

ASTM 12F Thermometer.
Range: –5 to +215F

250-000-12C

ASTM 12C Thermometer.
Range: –20 to +102C

250-000-41C

ASTM 41C Thermometer.
Range: 98 to 152C

K23425

Acrylic Heat Shield, with base
For high temperature bath on Dual-Twin Foam Test Apparatus.

344-100-01C

Certified Diffuser Stone.
Calibrated and certified for compliance with ASTM specifications for pore diameter and permeability.

344-100-001

Diffuser Stone, non-calibrated

344-005-001

Stainless Steel ‘Mott’ Diffuser

K43012

Test Cylinder
Replacement 1000mL cylinder. Includes retaining ring.

 

When inquiring about NIST traceable certified thermometers, please refer to the catalog number for the corresponding thermometer and replace the middle three zeros in the catalog number with 004. Example: 251-000-01C ASTM 1C Thermometer would be 251-004-01C ASTM 1C Certified Thermometer.


 