Welcome to EquiLab Canada Inc.

 

 

Home

Contacts

Resources

Links

 

Products

 

Environment

 

Life Science

 

General use

 

Petroleum Testers

 

Glassware

 

Consumables

 

Accessories

 

Spare Parts

 

 

 

 

Syringe pumps (Not for clinical use on humans)

 

NE-1000

NE-4000

NE-1600/NE-1800

NE-300

 

NE-1000

 

NE-1000 is fully programmable syringe pumps which can be operated as a stand-alone system or from a computer performing infusions and withdrawals and can hold one syringe up to 60 cc.

The infusion rates can be set from 0.73l/hr (1 cc syringe) to 2100 ml/hr (60 cc syringe) with a dispensing accuracy of 1%.

 

The pump can be programmed with up to 41 pumping phases that change the pumping rates, set dispensing volumes, insert pauses, control and respond to external signals, sound a buzzer.

The pump can be included in a network of up to 100 pumps controlled and monitored from one computer.

The pumps are not for clinical use on humans.

 

NE-4000 Double Syringe Pump

 

NE-4000 is fully programmable double syringe pumps which can be operated as a stand-alone system or from a computer performing infusions and withdrawals and can hold two syringes up to 60 cc. each

The infusion rates can be set from 1.459l/hr (1 cc syringe) to 7653 ml/hr (60 cc syringe) with a dispensing accuracy of 1%.

 

The pump can be programmed with up to 41 pumping phases that change the pumping rates, set dispensing volumes, insert pauses, control and respond to external signals, sound a buzzer.

The pump can be included in a network of up to 100 pumps controlled and monitored from one computer.

The pumps are not for clinical use on humans.

 

NE-1600/NE-1800 Multi-Syringe Pumps

 

NE-1600/NE-1800 are fully programmable syringe pumps which can be operated as a stand-alone system or from a computer performing infusions and withdrawals and can hold two, four, six or eight syringes up to 60 cc. each

The infusion rates can be set from 0.452l/hr (1 cc syringe) to 1451 ml/hr (60 cc syringe) with a dispensing accuracy of 1%.

 

The pump can be programmed with up to 41 pumping phases, which can be increased to 340 phases in upgraded models, that change the pumping rates, set dispensing volumes, insert pauses, control and respond to external signals, sound a buzzer.

The pump can be included in a network of up to 100 pumps controlled and monitored from one computer.

The pumps are not for clinical use on humans.

 

NE-300 Just infusion Pumps

 

NE-300 is an infusion pump which can hold syringes up to 60 cc and can pump continuously until it is stopped. The infusion rate can be changed during pumping. The pump remembers the previous settings. The maximum pumping rate is 1500 ml/hr with a 60 cc syringe.

The pumps are not for clinical use on humans.

 

 

Back to top