Life Science
General use
Petroleum Testers
Glassware
Consumables
Accessories
Spare Parts
|
|
|
Models
SM-200/300/510
& Models SE-300/510
Sterilizer Series
|

|
|
|
|
|
|

|
|
|
|
Space Saver:
Floor model - Top mounted door for easy vertical
loading, allowing 40% more space to be utilized. Each unit comes
equipped with 2 stackable baskets.
Mobile:
Smooth rolling casters and no mechanical
connections such as water supply, waste lines or steam exhaust are
necessary.
Simple and Accurate:
Fully automated operation - The HiTEC® IV CR
type microprocessor controller is now conveniently mounted on the front
panel of unit. Simply set your desired parameters of temperature and time
for sterilize and dry (SM series) or just sterilize (SE series) through
the easy to use, water resistant keypad.
Verification:
The digital set and readout accurately
monitors all aspects of the sterilization and drying process
(sterilization only for SE series) providing visible and audible
signals on its progress. An optional temperature recorder terminal or a
computer interface is ideal for verification of operating temperature.
Convenient:
Quick and slow release allows you to
sterilize both solid and liquid materials. Drying cycle, on SM series,
dries the glassware as well as any other articles, and is ready for use
immediately after operation.
Durable:
These compact sterilizers have a Type 304
(18-8) stainless steel interior as well as a cold rolled carbon steel
exterior finished with baked melamine for durability and appearance.
|
|
- SPECIFICATIONS -
|
|
SM-200
|
SM-210
|
SM-300
|
SM-310
|
SM-510
|
|
Capacity
|
cu. ft.
|
0.8
|
1.2
|
1.8
|
|
liters
|
22.7
|
34.0
|
51.0
|
|
Temperature Range
|
Sterilize
|
105°C to 123°C
|
105°C to 128°C
|
|
Dry
|
150°C to 180°C
|
|
Pressure Range
|
26.1 psi
|
29.0 psi
|
|
Temperature Control
|
Microprocessor PID, battery
back-up memory
|
|
Timer
|
1 minute to 99 hours and 59 minutes
(for both sterilize and dry)
|
|
Safety
|
Main
circuit breaker, overpressure safety valve, Microswitch, self diagnostic
circuitry: (Monitors any abnormality of temperature sensor, low water
sensor, SSR and heater)
|
|
Net Weight, lb. (kg)
|
143.3 (65)
|
176.4 (80)
|
187.4 (85)
|
|
Chamber
(ID×Depth)
|
inch
|
9.4×17.5
|
11.8×17.5
|
11.8×25.8
|
|
cm
|
23.9×44.5
|
30.0×44.5
|
30.0×65.5
|
|
Overall
(W×D×H)
|
inch
|
14.9×18.5×33.7
|
17.3×20.9×33.8
|
17.3×20.9×42.5
|
|
cm
|
37.8×47.0×85.6
|
43.9×53.1×85.6
|
43.9×53.1×108.0
|
|
Power Requirements
|
Volt, Amp
|
115V, 13A
|
220V,8A
|
115V, 17A
|
220V, 11A
|
|
Hz
|
50/60 Hz
|
|
|
SE-300
|
SE-310
|
SE-510
|
|
Capacity
|
cu. ft.
|
1.2
|
1.8
|
|
liters
|
34.0
|
51.0
|
|
Temperature Range
|
Sterilize
|
105°C to 128°C
|
|
Dry
|
N/A
|
|
Pressure Range
|
29.0psi
|
|
Temperature Control
|
Microprocessor PID, battery
back-up memory
|
|
Timer
|
1 minute to 99 hours and 59
minutes
(for both sterilize and dry)
|
|
Safety
|
Main
circuit breaker, overpressure safety valve, Microswitch, self diagnostic
circuitry: (Monitors any abnormality of temperature sensor, low water
sensor, SSR and heater)
|
|
Net Weight, lb. (kg)
|
176.4 (80)
|
187.4 (85)
|
|
Chamber
(ID×Depth)
|
inch
|
11.8×17.5
|
11.8×25.8
|
|
cm
|
30.0×44.5
|
30.0×65.5
|
|
Overall
(W×D×H)
|
inch
|
17.3×20.9×33.8
|
17.3×20.9×42.5
|
|
cm
|
43.9×53.1×85.6
|
43.9×53.1×108.0
|
|
Power Requirements
|
Volt, Amp
|
115V, 17A
|
220V, 11A
|
|
Hz
|
50/60 Hz
|
- ACCESSORIES -
|
Part No.
|
Image
|
Description
|
|
241-087
|
|
Standard
Basket for SM-200 series
|
|
241-088
|
Standard
Basket for SM/SE-300 series
|
|
241-089
|
Standard
Basket for SM/SE-510
|
|
241-096
|
|
Basket
w/ adjustable shelf for SM-200 series
|
|
241-095
|
Basket
w/ adjustable shelf for SM/SE-300 series
|
|
241-094
|
Basket
w/ adjustable shelf for SM/SE-510
|
|
SM-22-241096
|
|
Extra
Shelf for SM-200 series
|
|
SM-52-241044
|
Extra
Shelf for SM/SE-300 series & 510
|
|
241-097
|
|
Solid
Basket for SM-200 series
|
|
241-098
|
Solid
Basket for SM/SE-300 series & 510
|
Back to top
|
|